Mitsubishi Electric M800VW Series Programming Manual page 647

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.12 Chopping
PLC -> NC interface signals
Contact
Signal name
A
CHOPPING
[Function]
This signal validates the chopping function.
[Operation]
The chopping mode is entered at the rising edge of this signal.
Contact
Signal name
A
CHOPPING PARAMETER VALID
[Function]
This signal validates the chopping control data assigned to R register.
[Operation]
 The chopping mode is entered at the rising edge of this signal.
 This signal must be turned OFF after confirming the chopping start ready completion signal is turned ON.
"Chopping start ready completion" signal is included in the control status within the chopping control data.
Contact
Signal name
CHOPPING COMPENSATION UPDATE
A
PREVENTION REQUEST
[Function][Operation]
This signal prevents the chopping compensation amount from being updated.
[Related signals]
(1) Chopping compensation update prevented (CHPRCC: XC7F)
IB-1501668-B
Signal abbre-
$1
$2
viation
CHPS
YC30
YD70
Signal abbre-
$1
$2
viation
YC34
YD74
Signal abbre-
$1
$2
viation
CHPRCR
YCD7
YE17
626
$3
$4
YEB0
YFF0
$3
$4
YEB4
YFF4
$3
$4
YF57
Y1097