Output Instructions - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (1/2)
7 Basic Instructions

7.3 Output Instructions

7.3 Output Instructions
OUT(Y, M, L, F, B, SB, SM): Out instructions (Y, M, L, F, B, SB, SM)
Setting
Bit device
data
X
Y
M
L
F
D
[Instruction symbol] [Execution condition]
OUT
 Setting data
Setting data
D
Number of device to be turned ON and OFF
 Functions
 Operation results up to the OUT instruction are output to the designated device.
Operation results
Coil
OFF
ON
ON
ON
 Arithmetic errors
 There are no arithmetic errors associated with the OUT instruction.
IB-1501667-B
Usable devices
B SB
T SM V
T
C
Meaning
When using bit devices
Contact
A contact
B contact
Non-continuity
Continuity
Continuity
Non-continuity
Con-
Word device
stant
D
R/ZR W SW SD
Z
K
Bit device number (D)
Bit designation of word device (D)
When bit designation has been
made for word device
Designated bit
0
1
136
Digit
Pointer
designa-
Index
tion
H
P
Y35
D0.5
Data type
Bit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents