M800V/M80V Series PLC Programming Manual (1/2)
7 Basic Instructions
7.3 Output Instructions
7.3 Output Instructions
OUT(Y, M, L, F, B, SB, SM): Out instructions (Y, M, L, F, B, SB, SM)
Setting
Bit device
data
X
Y
M
L
F
D
○
○
○
○
○
[Instruction symbol] [Execution condition]
OUT
Setting data
Setting data
D
Number of device to be turned ON and OFF
Functions
Operation results up to the OUT instruction are output to the designated device.
Operation results
Coil
OFF
ON
ON
ON
Arithmetic errors
There are no arithmetic errors associated with the OUT instruction.
IB-1501667-B
Usable devices
B SB
T SM V
T
C
○
○
○
Meaning
When using bit devices
Contact
A contact
B contact
Non-continuity
Continuity
Continuity
Non-continuity
Con-
Word device
stant
D
R/ZR W SW SD
Z
K
○
○
○
○
○
Bit device number (D)
Bit designation of word device (D)
When bit designation has been
made for word device
Designated bit
0
1
136
Digit
Pointer
designa-
Index
tion
H
P
○
Y35
D0.5
Data type
Bit