9 Exclusive Instructions
9.1 ATC Exclusive Instruction

9.1.13 Display of Spindle Tool and Standby Tool

The tool mounted on the spindle or the tool to be mounted next on the spindle (standby tool) and tool No. in the magazine are
set and displayed on the tool registration screen. However, the spindle and standby tool Nos. can also be displayed on the
position display screen and tool length measurement screen that are often used. With this, the changes in the magazine pot
and spindle tool No. according to the tool selection command or tool change command can be confirmed.
 Position display screen
 Display tool selection parameter
A maximum of four standby tools can be displayed on the tool registration screen. The No. of the standby tool and the title to
be displayed on the monitor screen and setup screen, etc., are selected.
Display tool selection parameter (R10603)
F
E
D
C
B
A
9
8
Spare
IB-1501667-B
Spindle and
standby display
7
6
5
4
3
2
1
0
Selection of display tool
000000 : Spindle, standby 1
000001 : Spindle, standby 2
000010 : Spindle, standby 3
000011 : Spindle, standby 4
Others : Not display
Selection of display 1 : Display tool
0 : Do not display tool