Arbitrary Device Assignment - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (1/2)
3 Input/Output Signals
3.3 PLC Device Assignment of Digital Signal (DI/DO)

3.3.2 Arbitrary Device Assignment

Parameter setting for device arbitrary assignment
 By setting the parameter "#53001 RIO dev assign" to "1", the assignment method for PLC devices to be used for input/out-
put of each remote I/O unit station becomes arbitrary device assignment.
 For arbitrary device assignment, set the PLC devices for input and output to DI/DO (32 points) of each remote I/O unit sta-
tion by the parameters. Also, set the assignment of the operation panel I/O unit.
 Turn the power OFF and ON to enable arbitrary device assignment after the parameter settings.
 Set the input/output device assignment and high-speed input/output specification by the parameters for each station of all
remote units which have DI/DO function (except safety DI/DO). If all stations have not been set, the alarm "Y05 Initial
parameter error" will be issued when the power turns ON.
Name
Target channel No. #n
Target station No. #n (*2) #53012
DI device name #n
DI device No. #n
DO device name #n
DO device No. #n
High-speed input specifi-
cation #n
High-speed output speci-
fication #n
(*1) A set of RIO assignment parameters consists of eight parameters (from target channel number to high-speed output
specification) for one station.
(*2) Arbitrary device assignment cannot be performed for the system-occupied stations of RIO3 and operation panel I/O
unit-connected channels.
 The PLC devices that are valid for arbitrary device assignment are as follows:
PLC device
Word/Bit
X
Bit
Y
Bit
ZR
Word
Note
(1) Duplication check is not performed between the PLC devices which are set with machine input/output signal other
than the remote I/O such as CC-Link or PROFIBUS and PLC devices which are set with arbitrary device assignment.
If the PLC devices have duplicated, NC or PLC ladder can not be carried out correctly. When using machine input/out-
put signal other than the remote I/O, make sure to confirm that the PLC devices do not duplicate the PLC devices set
with arbitrary device assignment.
(2) Assignment cannot be performed for the devices corresponding to the system-occupied stations of RIO3. If you con-
nect the operation panel to any channel other than RIO3, assignment is also disabled for the devices corresponding to
the system-occupied stations of the said channel.
 Even when the RIO assignment parameters are set in the remote I/O unit stations which have the analog input/output and
safety DI/DO functions, the input/output is not carried out to the set PLC devices.
#1
-
#64
#53011
-
#53641
-
#53642
#53013
-
#53643
#53014
-
#53644
#53015
-
#53645
#53016
-
#53646
#53017
-
#53647
#53018
-
#53648
Input
Output
-
-
Parameter set No. (*1)
#65
-
#128
#53651
-
#54281
#53652
-
#54282
#53653
-
#54283
#53654
-
#54284
#53655
-
#54285
#53656
-
#54286
#53657
-
#54287
#53658
-
#54288
Assignable range
X0000 to X05FF
However, X400 to X5FF is in-
valid when PROFIBUS specifi-
cation is added.
Y0000 to Y05FF
However, Y400 to Y5FF is in-
valid when PROFIBUS specifi-
cation is added.
ZR5000 to ZR5999 (for input)
ZR6000 to ZR6999 (for output)
21
#129
-
#182
#54291
-
#54821
#54292
-
#54822
#54293
-
#54823
#54294
-
#54824
#54295
-
#54825
#54296
-
#54826
#54297
-
#54827
#54298
-
#54828
PLC device No. format
Hexadecimal
Hexadecimal
Decimal
IB-1501667-B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents