Mitsubishi Electric M800VW Series Programming Manual page 938

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
16 External PLC link
16.1 CC-Link
Master station
Remote register RWw
RWw 01 to RWw 00
For station
No. 1
RWw 03 to RWw 02
RWw 05 to RWw 04
For station
No. 2
RWw 07 to RWw 06
RWw 09 to RWw 08
For station
No. 3
RWw 11 to RWw 10
RWw 13 to RWw 12
For station
No. 4
RWw 15 to RWw 14
RWw 17 to RWw 16
For station
No. 5
RWw 19 to RWw 18
[Ver.1 RWr/RWw]
Master station -> Local station/Remote device station
 Master station
- The output status to the remote device station (RWw) and all local stations (RWr) is stored.
- Four words are used per station.
- Area for the remote I/O station is also secured.
 Local station
- The data received from the remote device station (RWw) and master station (RWw) is stored.
- Four words are used per station.
- Area for the remote I/O station is also secured.
Local station
Remote device station
(Station No.1 : Occupied 1 station)
(Station No.2 : Occupied 2 stations)
Remote register RWr
Remote register RWw
RWr 01 to RWr 00
RWr 03 to RWr 02
RWr 05 to RWr 04
RWw 01 to RWw 00
RWr 07 to RWr 06
RWw 03 to RWw 02
RWr 09 to RWr 08
RWw 05 to RWw 04
RWr 11 to RWr 10
RWw 07 to RWw 06
RWr 13 to RWr 12
RWr 15 to RWr 14
RWr 17 to RWr 16
RWr 19 to RWr 18
917
Remote I/O station (Station No.4
Local station
: Occupied 1 station)
(Station No.5 : Occupied 1 station)
Remote register RWr
RWr 01 to RWr 00
RWr 03 to RWr 02
RWr 05 to RWr 04
RWr 07 to RWr 06
RWr 09 to RWr 08
RWr 11 to RWr 10
RWr 13 to RWr 12
RWr 15 to RWr 14
RWr 17 to RWr 16
RWr 19 to RWr 18
IB-1501668-B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents