Accumulated Power Consumption History - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.40 Power Consumption Computation

14.40.5 Accumulated Power Consumption History

According to the parameters "#1371 PwrIntegIntvl (Power consumption accumulation interval)" and "#1392 StartTimeIPC
(Power consumption accumulation start time)", the control records the accumulated power consumption (1) and (2) as shown
in the figure below and the time stamp (Accumulation start time) in a file so that the accumulation data can be obtained as an
accumulated consumption history file. Among the values, a plus means power consumption, while a minus means power
regeneration.
The signals "Power consumption computation: Enable consumption accumulation 1 to 4 (IPCE1 to 4: Y724 to 7)" are not used
for creating the accumulated power consumption history.
Total power
=
consumption
(1) Accumulated consumption of entire drive system
Illustrated below is a timing chart of the operation to obtain the accumulated power consumption history data.
(1) Set the accumulation interval (#1371) to "4"
Set the start time (#1392) to "10"
(2) Power OFF/ON
ON
OFF
Power
6:00
10:00
T
Time
Hist. 1
Hist. 2
 How to start creating accumulated power consumption history
 Set the "#1371 PwrIntegIntvl (Power consumption accumulation interval)" in the range of 0 to 999 [hr]. Also set the "#1392
StartTimeIPC (Power consumption accumulation start time)" in the range of 0 to 23 [o'clock]. It is not possible to specify the
date with this parameter.
 Turn the power OFF and ON again. If you have changed the parameter setting in (1), the accumulated power consumption
history is cleared, and new consumption accumulation is started. If you set the "#1371 PwrIntegIntvl (Power consumption
accumulation interval)" to 0 [hr], however, the accumulation will not start.
IB-1501668-B
Present value
Drive system total consumption
Variation in drive system
Servo axis
Spindle
+
consumption
consumption
Clear the history.
Start the consumption accumulation.
14:00
22:00
18:00
Hist. 5
Hist. 3
Hist. 4
Fixed consumption
Fixed
consumption
correction
+
+
(R register)
(parameter)
Integrate
(2) Accumulated consumption of
devices other than drive system
T: Consumption accumulation interval = 4
2:00
6:00
10:00
Hist. 6
Hist. 7
888
Non-drive
consumption
+
(R register)
14:00
18:00
Hist. 8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents