M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.33 PLC Axis Control
Remaining distance
The remaining distance of the movement data output to the machine system is expressed.
Remaining distance (input unit)
(1st axis)
Note
(1) Refer to the explanations of "#1003 iunit" and "#1005 plcunit" in "14.33.1 Specifications" for details on the unit.
(2) The remaining distance of the PLC axis, to which the PLC axis control valid signal is ON, is automatically updated.
14.33.5 Timing Chart
For rapid traverse mode or cutting feed mode
PLC axis control
valid signal
Start
busy
den
move
Speed
For jog feed mode
PLC axis control
valid signal
Start
busy
den
move
Speed
Note
(1) The axis moves by jog feed only during start ON.
811