M800V/M80V Series PLC Programming Manual (2/2)
13 Spindle Control
13.13 Spindle Oscillation
Note
(1) Stops and starts of spindle oscillation are executed with the level trigger for the spindle oscillation command signal, but
stops and starts of spindle oscillation are executed with the edge trigger for scenarios when emergency stop has been
executed. As spindle oscillation restarts from the stopped position, oscillation may not start from the same initial oscilla-
tion position.
Emergency stop
Spindle oscillation
in progress signal
(X18C8)
Spindle oscillation
command signal
(Y18C8)
Spindle position
IB-1501668-B
Emergency stop ON causes
spindle to stop and turns
spindle oscillation in progress
signal OFF
Does not restart even
though emergency
stop is OFF
552
Turn ON after turning OFF will
start oscillation from that position