16 External PLC link
16.1 CC-Link
 When data link control is compulsorily transferred from standby master station to master station
The parts enclosed with broken or dotted lines in "Program example when using standby master function (master station
duplex function)" need to be changed to as shown below.
M10
M200
SB46
M11
SB5D
M10
Control start relay when master station is in operation
M11
Control start relay when standby station is in operation
M200
Forced master switching request
SB0C
Forced master switching
SB46
Forced master switching executable status
SB5D
Forced master switching completion signal
A control program when master station is operating
A control program when standby master station
(local station) is operating
SET
SB0C
MCR
N0
RST
SB0C