M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.2 Manual Speed Command
If the manual speed command valid signal is turned ON during the cycle start, the automatic operation is paused. However,
even if the manual speed command valid signal is turned ON while executing the thread cutting, the manual speed com-
mand is kept invalid until the next block's end point of where the thread cutting is completed.
X
Invalid up to here
Thread
cutting
Both manual and automatic interlocks are available when the manual speed command is valid.
Direction designated in the machining program
Example) 100/-100 is set for the X direction of the 1st axis
Program X100
(Forward run)
Automatic interlock+: Available
Automatic interlock-: Not available
Manual interlock+: Available
Manual interlock-: Not available
(Reverse run)
Automatic interlock+: Available
Automatic interlock-: Not available
Manual interlock+: Not available
Manual interlock-: Available
Operation example
<Machining program>
N100 G91 G0 X10. Y10.
N200 G1 X10. F1000
N300 G3 Y20. J10. F200
N400 G1 X-10. F1000
N500 G1 Y-20.
N600 M30
IB-1501668-B
Manual speed
command valid
signal is
turned ON
Z
Program X-100
(Forward run)
Automatic interlock+: Not available
Automatic interlock-: Available
Manual interlock+: Available
Manual interlock-: Not available
(Reverse run)
Automatic interlock+: Not available
Automatic interlock-: Available
Manual interlock+: Available
Manual interlock-: Not available
N400
N500
N200
Automatic operation
pause
N100
566
N300