M800V/M80V Series PLC Programming Manual (2/2)
16 External PLC link
16.1 CC-Link

16.1.3.3 Automatic Refresh

Data transfer between the CC-Link master/local module and the NC built-in PLC device is performed automatically. Set the
destination device to be automatically refreshed to the parameters "#24014+40(n-1) RX dev name" to "#24025+40(n-1) SW
dev No." ("n" indicates slot No.).
The devices possible to set as destination devices in the automatic refresh are as follows.
Device name
X
X0 to X5FF (Do not duplicate the devices used by actual I/O)
Y
Y0 to Y5FF (Do not duplicate the devices used by actual I/O)
M
M0 to M61439
L
L0 to L1023
B
B0 to BDFFF
D
D0 to D4095
(User backup area)
R8300 to R9799, R18300 to R19799, R28300 to R29799
R
(User work area)
R9800 to R9899, R19800 to R19899, R29800 to R29899
ZR
ZR0 to ZR13311 (*1)
W
W0 to W2FFF
SB
SB0 to SB3FF
SW
SW0 to SW3FF
(*1) Since ZR device has specific uses such as PLC and CNC interfaces and parameter interfaces, be aware when setting it
as a forwarding destination to refresh.
Note
(1) When the multi-project function is used, the devices M, L, B, D, W, SB, and SW are assigned as the first project device.
IB-1501668-B
Device range
922
RX, RY, SB
RWr, RWw, SW
RX only
×
RY only
×
SB only
×
×
SW only