EXP, EXPP: Exponent operation on floating-point data (single precision)
Setting
Bit devices
data
X
Y
M
L
F
S
D
△ : This is not available with ST.
[Instruction symbol] [Execution condition]
EXP
EXPP
Setting data
Setting data
Data for which the exponential value is obtained or the first number of the device
S
where data is stored.
D
The first number of the device to store the operation result.
Functions
EXP
Returns the exponent of the value designated by (S) and stores the operation result in the device designated by (D).
S+1
S
e
(
32-bit floating-point real
number
Exponent operations are calculated with the base (e) as "2.71828".
When setting input values from programming tools, rounding errors may occur.
For precautions when setting input values from programming tools, refer to "6.3.4 Single/Double-Precision Real Number
Data".
Operation errors
In the following cases, an arithmetic error occurs, the error flag (SM0) turns ON, and an error code is stored at SD0.
- The designated device value is "-0", unnormalized number, nonnumeric, or ± ∞ . (Error code: 35)
- The operation result exceeds the following range. (When an overflow occurs) (Error code: 36)
| Operation result | < 2
IB-1501667-B
Usable devices
B SB
T SM V
T
C
○
○
○
○
Command
Command
Meaning
D+1
D
)
32-bit floating-point real
number
128
Con-
Word devices
stant
D
R/ZR W SW SD
Z
○
○
○
○
○
△
○
○
○
○
○
△
396
Digit
Pointer
designa-
Index
tion
E
P
○
○
indicates the sign "EXP".
S
D
P
S
D
Data type