High-Speed Simple Program Check; Function Enabling Conditions - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function

14.8 High-Speed Simple Program Check

14.8 High-Speed Simple Program Check
This function checks whether a program error occurs by operating the machining program without the axes movements.
The estimated machining time can be checked in time shorter than the actual execution time of the machining program.
This function is valid with the "High-speed simple program check" signal ON .
The machining program is operated in the reduced time according to the coefficient which is set to the time reduce coefficient.
The estimated machining time of the machining program is output to time measurement output.
The miscellaneous command code which outputs strobes can be allocated arbitrarily with the parameter during the high-
speed simple program check.
Actual execution time
Execution time by high-speed simple
program check (example: 1/4)
Estimated machining time to be output [ms]

14.8.1 Function Enabling Conditions

This function is enabled/disabled using PLC signals. (The following signals are common part system signals.)
Input/output
Device No.
NC -> PLC
Y73E
SMLK
NC -> PLC
X712
SMLKO
NC -> PLC
R378
Reducing execution time according to time reduce coefficient
Converting to time of normal operation
Signal name
High-speed simple program check mode
High-speed simple program check mode
ON
Time reduction coefficient
595
Description
Turning this signal ON turns ON the high-
speed program check ON signal.
When this signal is on, the high-speed sim-
ple program check function is enabled.
This reduces the execution time of the
high-speed simple program check.
IB-1501668-B