Index Register Z - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (1/2)
4 Explanation of Devices
4.4 Detailed Explanation of Devices

4.4.12 Index Register Z

 The index register is used as ornaments for the device. (*1)
159
165
 The index register has a 1-point 16-bit configuration, and can be read and written in 16-bit units.
 The data stored in the index register is cleared when the power is turned OFF.
 Values that can be stored:
Decimal -32768 to 32767
Hexadecimal 0 to FFFF
 Devices/labels can be used for indexes in array labels by setting the bit selection parameter "#6471/bit1" (array valid) to "1".
In this case, Z16 to Z19 are used to create the compilation result. Do not use Z16 to Z19 in sequence programs.
Restart the CNC after setting the bit selection parameter "#6471/bit1".
 When the bit selection parameter "#6471/bit1" is "1", the number of device points for index resisters is 10 points (Z0 to Z9).
When the bit selection parameter is "0", the number of device points for index resisters is 14 points (Z0 to Z13).
(*1) Refer to "6.4 Index Modification" for the modifiaction target device.
IB-1501667-B
MOV K3
Z0
MOV
K4X0 D5Z0
D5Z0 indicates D(5+Z0)=D8