M800V/M80V Series PLC Programming Manual (1/2)
9 Exclusive Instructions
9.1 ATC Exclusive Instruction
9.1.9 File Register (R Register) Assignment and Parameters
Control parameter contents
R10600
F
E
D
C
B
A
Max. number of standby
displayed: 4
For details on the control parameters, refer to "Examples of Tool Registration Screen".
Arbitrary setting of number of tools per magazine
This function allows the number of tools per magazine to be set freely.
When not setting arbitrarily
The number of magazine rows is set to the maximum three rows, and the number of tools that can be registered is set to
maximum 120 tools/magazine.
The magazine tool data assignment is fixed.
When setting arbitrarily
There is a maximum of five magazine rows, and the number of tools that can be registered is a total of 360 tools for all
magazines.
Set the number of tools per magazine in the "number of magazine designation" register.
(If there are any magazines not being used, set the designation register to 0.)
"Number of magazine designation" register
No. 1 magazine: R10610
No. 2 magazine: R10611
No. 3 magazine: R10612
No. 4 magazine: R10613
No. 5 magazine: R10614
The magazine tool data is assigned for the set tools in order from No. 1 magazine based on the set number of tools.
IB-1501667-B
9
8
7
6
5
4
3
2
1
0
0: T4-digit
1: T8-digit
0: Magazine starts from "1"
1: Magazine starts from "0"
Number of tools per magazine
0: Do not set arbitrarily
1: Set arbitrarily
432