14.20 Diagnosis Data Output

14.20 Diagnosis Data Output

14.20.1 Outline

Diagnosis data output is a function designed to output the information on when to exchange the life-limited parts of the NC
and its peripherals.
The information, which is output to ZR registers, can be used for preventive maintenance, including lifetime prediction.

14.20.2 Function Details

The output data is automatically reset at the time of replacing the specific product (NC unit, drive or motor). (Note)
If you have replaced the part (battery, etc.) only, you can reset the data by writing 0 in the ZR register. After the reset, reboot
the NC.
Note
(1) To avoid any unintended reset at a tentative replacement, the control performs automatic reset upon the first NC startup
after 24 hours have passed after the replacement. Using the ZR register value, you can adjust the length of time from
replacement until data clear.
Table below shows the data items to be output.
The control outputs the information for each servo axis or spindle. The information of spindle C axis is output to the spindle's
ZR registers.
The information of a spindle-mode servo axis is also output to the spindle's ZR registers.
Category
Data item
Battery ex-
NC
Control
change
Battery ex-
change
(for each servo
axis)
Drive unit
Battery ex-
change
(for each spindle)
Cumulative trav-
el distance
Drive
(for each servo
axis)
Insulation resis-
tance
Motor
(for each servo
axis)
Insulation resis-
tance
(for each spindle)
IB-1501668-B
Unit
Auto reset
ZR register
ZR12404
min
At NC exchange
ZR12405
ZR12608
ZR12609
to
ZR12670
ZR12671
At drive ex-
hr
change
ZR12688
ZR12689
to
ZR12702
ZR12703
ZR12946
ZR12947
m/rev
None
to
ZR13008
ZR13009
ZR12784
ZR12785
to
ZR12846
ZR12847
At motor ex-
change
ZR12848
ZR12849
to
ZR12862
ZR12863
688
Details
Length of time the battery for the NC unit memory has
been used.
Length of time the battery for the drive unit memory has
been used.
Accumulated travel distance of each motor
For a rotary axis, the number of revolutions is output.
Insulation resistance of each motor
(only for drive unit E/EH Series)
0 to 100MΩ (Zero means 1MΩ or less)
If your drive unit does not support this function, or if the
data has not been obtained from the drive unit, "-1"
(0xFFFFFFFF) is output.