Mitsubishi Electric M800VW Series Programming Manual page 689

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.18 Interference Check III
Mode enable command
While the "Interference check III: Interference check III mode" signal (Y76A) is ON after the "Interference check III: Enable
interfering object selection data" signal (Y769) or the enable interference check III setting data command (G186) is executed,
the interference check between interfering objects is performed. While the interference check III is being executed, the
"Interference check III: In interference check III mode" signal (X772) is turned ON.
After NC power is turned ON, if the interference check III mode is turned ON without executing the "Interference check III:
Enable interfering object selection data" signal (Y769) or the enable interference check III setting data command (G186) even
once, the operation error (M03 1001) occurs.
Timing chart
The timing when the interfering object data and interference check III mode are enabled is described below.
[In the case interfering object data is enabled with G code]
Enable interference check
III setting data command
(G186)
Interfering data pattern [1] is set.
Interference check III:
Interference check III
mode (Y76A)
Interference check III:
In interference check III
mode (X772)
State of interference
check III
[In the case interfering object is enabled with PLC device]
Interference check III:
Enable interfering object
selection data (Y769)
Interfering data pattern [1] is set.
Interference check III:
Interfering object selection
data setting completed (X771)
Interference check III:
Interference check III mode
(Y76A)
Interference check III:
In interference check III mode
(X772)
State of interference
check III
The interference check is performed with the interference
execution data which is already set. During execution,
"Interference check III: In interference check III mode"
(X772) will be turned ON.
If you turn OFF and ON the "Interference check III: mode" signal, the interfering data you set lastly is used for the interference
check between interfering objects.
IB-1501668-B
G186
Check not
Check is performed
performed
with data pattern [1]
Interfering data pattern [2] is set.
"Interference check III: Interfering object selection data setting completed" (X771)
will be turned OFF at the same timing that "Interference check III: Enable
interfering object selection data" (Y769) is turned OFF.
Check not
performed
G186
Interfering data pattern [2] is set.
Check is performed
with data pattern [2]
Check is performed
Check is performed
with data pattern [2]
with data pattern [1]
When "Interference check III: Interference check III mode" (Y76A)
is turned OFF, the execution of the interference check will end.
"Interference check III: In interference check III mode" (X772) will
also be turned OFF.
668
Check not
performed
Check not
performed