Mitsubishi Electric M800VW Series Programming Manual page 905

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.40 Power Consumption Computation
As the figure below illustrates the flow of the power consumption monitor process. The items (1) to (15) in this figure
correspond to the items given in the previous page.
<<Set by MTB>>
Ladder, APLC
(PLC)
R register (PLC -> NC)
(5) Drive system's fixed consumption
correction
(7) Consumption of devices other
than drive system
Y device (PLC -> NC)
- Clear consumption accumulation 1
to 4
- Enable consumption accumulation 1
to 4
X device (NC -> PLC)
- Clearing consumption
accumulation 1 to 4 complete
- Consumption accumulation ON 1 to
4
Parameter
(HMI)
Parameters
- Power consumption
accumulation interval
- Power consumption
accumulation start time
(4) Drive fixed power consumption
- Stall torque for power
consumption
- Short-time rated output for
power consumption (L/H coil)
- Coil switch function ON/OFF
- Speed detection set value
- Base speed
Note
(1) The use of custom API library function (melReadData) allows you to obtain the present power consumption data and
accumulated power consumption data.
IB-1501668-B
<<Process in NC>>
Servo axes
Spindle
Drive unit
(2) Present consumption of servo axes in drive system (variation)
(3) Present consumption of spindles in drive system (variation)
(1) Total power consumption
(2) Present consumption of servo axes
in drive system (variation)
(3) Present consumption of spindles in
NC
drive system (variation)
(8) Total accumulated power
consumption 1 to 4
(9) Drive system fixed accumulated
power consumption correction 1 to 4
(10) Accumulated consumption of
servo axis in drive system (variation) 1
to 4
(11) Accumulated regeneration of servo
axis in drive system (variation) 1 to 4
(12) Accumulated consumption of
spindle in drive system (variation) 1 to
4
(13) Accumulated regeneration of
spindle in drive system (variation) 1 to
4
884
<<Obtained by MTB>>
R register (NC -> PLC)
(6) Present consumption of entire drive system
(14) Accumulated consumption of entire drive
system 1 to 4
(15) Accumulated consumption of devices
other than drive system 1 to 4
(Section/Sub-section)(Note)
Ladder, APLC
(PLC)
melReadData
Power
monitor
screen

Hide quick links: