M800V/M80V Series PLC Programming Manual (1/2)
11 Parameters
11.1 PLC Constants
 Extended area
Up to 750 PLC constants can be secured by using the user backup area (R8300 to R9799) as the extended area. The
extended area start register and number can be set with the parameters. A total of 900 PLC constants can be set with 150
(#18001 to #18150) in the basic area and up to 750 (#18151 to #18900) in the extended area.
Set up data is stored in a file register and is backed up. In contrast, if data is stored in the file register corresponding to PLC
constant by using sequence program MOV instruction, etc., it is backed up.
However, display remains unchanged. Display another screen once and then select the screen again.
750 PLC constants are set (the setting range is ±8 digits). (Signed 4-byte binary data)
[PLC constant No. and R register correspondence table]
Item (# No.)
LOW side
PLC constant #151
(#18151)
HIGH side
LOW side
PLC constant #152
(#18152)
HIGH side
LOW side
PLC constant #153
(#18153)
HIGH side
...
LOW side
PLC constant #898
(#18898)
HIGH side
LOW side
PLC constant #899
(#18899)
HIGH side
LOW side
PLC constant #900
(#18900)
HIGH side
The extended area quantity is set with basic common parameter #1326.
# No.
Item
1326
PLC Const Ext. Number
Corresponding reg-
Details
ister
R8300 to R9799
The area for the num-
Data type parameters
ber determined with
which can be used in user
parameter #1326 is
PLC
continuously se-
cured.
Details
 Set number of PLC constant extension points.
 This is valid after the power is turned OFF and
ON.
457
Setting range
-99999999 to 99999999
(Signed 8-digit integer)
Setting range
0 to 750
IB-1501667-B