14.40 Power Consumption Computation
 Example of accumulated power consumption history file
When the "#1371 PwrIntegIntvl (Power consumption accumulation interval)" is set to "24", and the "#1392 StartTimeIPC
(Power consumption accumulation start time)" is set to "0":
Accumulated
Accumulation
consumption of entire
start time
drive system
31 days ago
30 days ago
29 days ago
28 days ago
27 days ago
26 days ago
25 days ago
24 days ago
23 days ago
:
8 days ago
7 days ago
6 days ago
5 days ago
4 days ago
3 days ago
2 days ago
1 day ago
Today
 Number of history data
The data with accumulation values can be obtained up to 48 pieces. If the number of pieces to record exceeds 48, the latest
data is always recorded. At this time, you can include the data without accumulation values in the middle of the history data.
However, if two or more data without accumulation values come in a row, only the top data (the data with the oldest time
stamp) is displayed. The maximum number of history data is 96.
If you record the data with accumulation value and data without accumulation value alternatively, it reaches the maximum
value.
The top data (the data with the oldest time stamp) of the history file is always the data with accumulation value.
 Display of history data
History data is displayed in a chronologically ascending order of the time stamp (Accumulation start time).
If up to the Nth history data have been recorded, the (N+1)th and subsequent data are not displayed. (N = 1 to 95)

14.40.6 Precautions

(1) When you clear each of Accumulated power consumption 1 to 4, and if you turn ON and then OFF the "Power consump-
tion computation: Clearing consumption accumulation 1 to 4 (IPCC1 to 4: Y700 to 3)" without checking the ON status of
the "Power consumption computation: Clearing consumption accumulation 1 to 4 complete (IPCCC1 to 4: X708 to B)",
Accumulated power consumption 1 to 4 may not be cleared.
(2) If a spindle has the spindle/C axis control, the power consumed during C axis control is not calculated as the servo axis
power consumption, but as the spindle power consumption.
(3) Set "#13228 SP228 SFNC8/bit0 to 2" (Load display selection) to "011" (Load display High-cycle).
If you enter "000" (Normal), the power consumption is not properly calculated.
(4) If you turn OFF and ON the power with "#1371 PwrIntegIntvl (Power consumption accumulation interval)" set to "0", Accu-
mulated power consumption is cleared.
Accumulated
consumption of devices
other than drive system
13865
564
21567
1123
16235
856
136
4098
0
0
0
0
0
0
600
13245
15000
756
:
:
14097
634
9854
423
0
0
15432
745
10053
422
10000
634
0
0
0
0
Obtain the history file
PWCSP, CSV
Jan/10/2011/0, 13865, 564
Jan/11/2011/0, 21567, 1123
Jan/12/2011/0, 16235, 856
Jan/13/2011/0, 4098, 136
Jan/14/2011/0, 0, 0
Jan/17/2011/0, 13245, 600
Jan/18/2011/0, 15000, 756
:
Feb/2/2011/0, 14097, 634
Feb/3/2011/0, 9854, 423
Feb/4/2011/0, 0, 0
Feb/5/2011/0, 15432, 745
Feb/6/2011/0, 10053, 422
Feb/7/2011/0, 10000, 634
Feb/8/2011/0, 0, 0
891
Data with
accumulation values
Data without
accumulation values
* The history data for
which you never turned
ON the power before
passing the
consumption
accumulation interval
(#1371)
IB-1501668-B