M800V/M80V Series PLC Programming Manual (1/2)
8 Function Instructions
8.4 Data Transfer Instructions
FMOV, FMOVP: 16-bit identical data batch transfer
Setting
Bit devices
data
X
Y
M
L
F
S
D
n
[Instruction symbol] [Execution condition]
FMOV
FMOVP
 Setting data
Setting data
S
S Data to transfer, or head number of device storing data to transfer
D
Head No. of the destination device
n
Number of transfers
 Functions
 Transfers 16-bit data from device designated by "S" to location n-points from device designated by "D".
Transmission
b15
b0
S
H3456
 Operation errors
 In the following cases, an arithmetic error occurs, the error flag (SM0) turns ON, and an error code is stored at SD0.
- In the case where a part of device area between D and n-th device does not exist. (Error code: 82)
IB-1501667-B
Usable devices
B SB
T SM V
T
C
Command
Command
Meaning
b15
b0
D
H3456
D+1
H3456
D+2
H3456
n
D+(n-2)
H3456
H3456
D+(n-1)
Con-
Word devices
stant
D
R/ZR W SW SD
Z
K
240
Digit
Pointer
designa-
Index
tion
H
P
FMOV
S
D
n
FMOVP
S
D
n
Data type
BIN 16 bits