Mitsubishi Electric M800VW Series Programming Manual page 557

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
13 Spindle Control
13.11 Spindle Synchronization Control ll
 Multi-step acceleration/deceleration
Up to eight steps of acceleration/deceleration time constants for spindle synchronization can be selected according to the
spindle rotation speed.
(F)
Sptc3
Sptc2
Sptc1
(1)
(2)
(3)
IB-1501668-B
(F) Rotation speed
(T) Time
(1) Time required from stopped state to sptc1 setting rotation speed
spt * (sptc1/maximum rotation speed)
(2) Time required from sptc1 to sptc2 setting rotation speed
spt * ((sptc2-sptc1)/maximum rotation speed) * spdiv1
(3) Time required from sptc2 to sptc3 setting rotation speed
spt * ((sptc3-sptc2)/maximum rotation speed) * spdiv2
(T)