Present Power Consumption; Accumulated Power Consumption 1 To 4 - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.40 Power Consumption Computation

14.40.3 Present Power Consumption

During the power ON, you can obtain the present power consumptions (1) to (7) as illustrated in Figure below. Among the
values, a plus means power consumption, while a minus means power regeneration.
(1) Total power
=
consumption
Illustrated below is a timing chart of the operation to obtain the present consumption data.
ON
Power
OFF
Present power
consumption

14.40.4 Accumulated Power Consumption 1 to 4

You can obtain the following accumulated power consumption data (8) to (15) while the power is ON that are accumulated in
accordance with the signals "Power consumption computation: Enable consumption accumulation 1 to 4 (IPCE1 to 4: Y724 to
7)" and "Power consumption computation: Clearing consumption accumulation 1 to 4 (IPCC1 to 4: Y700 to 3)".
Among the values, a plus means power consumption, while a minus means power regeneration. Note however that the
regeneration power (3) and (5) are expressed with positive values.
(1) Total
power
=
consumption
(8) Total accumulated power
consumption 1 to 4
(10) Accumulated consumption of servo axis in drive system (variation) 1 to 4
(11) Accumulated regeneration of servo axis in drive system (variation) 1 to 4
IB-1501668-B
(6) Drive system total consumption
Variation in drive system
(2) Servo
(3) Spindle
axis
+
consumption
consumption
Obtainable
Present power consumption
(6) Drive system total consumption
Variation in drive system
(2) Servo
(3) Spindle
axis
consumption
+
consumption
Integrate
(14) Accumulated regeneration of
entire drive system 1 to 4
(12) Accumulated consumption of spindle in
drive system (variation) 1 to 4
(13) Accumulated regeneration of spindle in
drive system (variation) 1 to 4
Accumulated power consumption data
(5) Fixed
(4) Fixed
consumption
consumption
+
+
correction
(parameter)
(R register)
Obtainable
(5) Fixed
(4) Fixed
consumption
consumption
+
+
correction
(parameter)
(R register)
(15) Accumulated consumption of devices
other than drive system 1 to 4
(9) Drive system fixed accumulated power
consumption correction 1 to 4
886
(7) Non-drive
consumption
+
(R register)
Obtainable
(7) Non-drive
consumption
+
(R register)

Hide quick links:

Advertisement

Table of Contents
loading