Available Got Function; Device Range Accessible From Got - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.24 GOT Connection

14.24.4 Available GOT Function

Available functions on GOT when connected with the NC differ depending on GOT model or connection method. For details,
refer to each GOT manual.
GOT2000 Series User's Manual (Hardware) SH-081194
GOT2000 Series User's Manual (Utility) SH-081195
GOT2000 Series User's Manual (Monitor) SH-081196
GOT2000 Series Connection Manual (Mitsubishi Electric Products) SH-081197
GOT2000 Series Connection Manual (Non-Mitsubishi Electric Products 1) SH-081198ENG
GOT2000 Series Connection Manual (Non-Mitsubishi Electric Products 2) SH-081199ENG
GOT2000 Series Connection Manual (Microcomputers, MODBUS/Fieldbus Products, Peripherals) SH-081200ENG
GT SoftGOT2000 Version1 Operating Manual SH-081201ENG
GT Designer3 (GOT2000) Screen Design Manual SH-081220

14.24.5 Device Range Accessible from GOT

The following table shows PLC device type and device range accessible from GOT.
PLC de-
Accessible range
vice
M
M0 to M61439(61440 points)
SM
SM0 to SM2047(2048 points)
L
L0 to L1023(1024 points)
F
F0 to F2047(2048 points)
V
V0 to V511(512 points)
X
X0 to X1FFF(8192 points)
Y
Y0 to Y1FFF(8192 points)
B
B0 to BDFFF(57344 points)
SB
SB0 to SB3FF(1024 points)
D
D0 to D4095(4096 points)
SD
SD0 to SD2047(2048 points)
R
R0 to R32767(32768 points)
ZR
ZR0 to ZR13311(13312 points)
W
W0 to W2FFF(12288 points)
SW
SW0 to SW3FF(1024 points)
TI
TI0 to TI2047(2048 points)
TO
TO0 to TO2047(2048 points)
TA
TA0 to TA2047(2048 points)
CI
CI0 to CI511(512 points)
CO
CO0 to CO511(512 points)
CA
CA0 to CA511(512 points)
STI
STI0 to STI127(128 points)
STO
STO0 to STO127(128 points)
STA
STA0 to STA127(128 points)
When setting the device which does not exit in the NC to GOT object, the object is not displayed on GOT. Unrelated object
may not be displayed on GOT screen.
By setting the number of reading device points to "1" with the setting of GOT connected device or SoftGOT communication
setting, the phenomenon that the unrelated object is not displayed can be prevented; however, the communication load
becomes large.
IB-1501668-B
When using multi-project function
(When the additional specification of 6 PLC
projects is valid)
Project total maxi-
Accessible range
mum points
M0 to M61439
122880 points
SM0 to SM2047
2048 points
L0 to L2047
2048 points
F0 to F2047
2048 points
V0 to V1023
1024 points
X0 to X1FFF
8192 points
Y0 to Y1FFF
8192 points
B0 to B1BFFF
114688 points
SB0 to SB7FF
2048 points
D0 to D8191
8192 points
SD0 to SD2047
2048 points
R0 to R32767
32768 points
ZR0 to ZR13311
13312 points
W0 to W5FFF
24576 points
SW0 to SW7FF
2048 points
TI0 to TI4095
4096 points
TO0 to TO4095
4096 points
TA0 to TA4095
4096 points
CI0 to CI1023
1024 points
CO0 to CO1023
1024 points
CA0 to CA1023
1024 points
STI0 to STI255
256 points
STI0 to STO255
256 points
STI0 to STI255
256 points
720
Details
Temporary memory
Special relay
Latch relay
Temporary memory
Edge relay
Input signal to PLC
Output signal from PLC
Link relay
Special relay
Data register
Special register
File register
File register
Link register
Special register
Timer (coil)
Timer (contact)
Timer (present value)
Counter (coil)
Counter (contact)
Counter (present value)
Integrated timer (coil)
Integrated timer (contact)
Integrated timer (present value)