Relation With Other Functions - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
27 Setting the Machine Error Compensation

27.3.5 Relation with Other Functions

(1) Memory-type Pitch Error Compensation
This function can be used simultaneously with the memory-type pitch error compensation.
As shown in the figure below, when the error profile consists of both cyclic errors and non-cyclic errors, a higher
accuracy of compensation can be achieved by combining the memory-type pitch error compensation and this
function.
Error
Compensates in accordance
IB-1501268-K
Error
Cyclic
with cyclic error.
Machine position
Non-cyclic
Error
Compensates by memory-type
pitch error compensation.
538