Function Enabling Conditions - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.19 Machine Group-Based Alarm Stop

14.19.2 Function Enabling Conditions

The following settings are required to enable this function.
(1) Set "1" in "#1471 mgralmstp (Enable machine groupwise alarm stop)".
(2) Set the machine group number as follows.
[Servo axis]
 Set the machine group number of each axis in "#1605 mgrnum (Machine group No.)".
 When the machine group number is set to "0", the axes will decelerate and stop even if an alarm occurs in any machine
group.
[Spindle]
 There are two types of setting methods to set the machine group number as a single or multiple machine groups. The
types can be switched by "#3195 mgrsptyp (Spindle's machine group setting type)".
0 : Set single machine group number
1 : Set multiple machine group number
 When "0" is set in "#3195 mgrsptyp (Spindle's machine group type)" , set the machine group number in "#3196 mgrsp-
num1 (Spindle's machine group No. 1)".
When "0" is set in "#3196 mgrspnum1 (Spindle's machine group No. 1)", the spindle decelerates and stops even if an
alarm occurs in any machine group.
 When "1" is set in "#3195 mgrsptyp (Spindle's machine group type)", set the machine group number in "#3197 mgrsp-
num2 (Spindle's machine group No. 2)".
When "00" is set in "#3197 mgrspnum2 (Spindle's machine group No. 2)", the spindle continues the operation even if an
alarm occurs in any machine group. If you want to make the spindles to decelerate and stop for all machine groups, set
"FF" in "#3197 mgrspnum2 (Spindle's machine group type)".
(3) The group settings of the machine group number become effective when the power is turned OFF and ON again after
entering the parameter values.
(4) When all axes are set to the same machine group, the function is invalid.
[Flow chart of the validity condition settings]
Use or not use of
this function
Machine group for feed
axes/PLC axes
Setting type of the machine
group for spindles
Machine group for spindles
Enable machine groupwise alarm stop
(#1471 mgralmstp)
Spindle's machine group setting type
(#3195 mgrsptyp)
Single machine group
Multiple machine groups
673
Not use
Set to be disabled ("0")
Use
Set to be enabled ("1")
Set a machine group number of each axis
in "Machine group No. (#1605 mgrnum)"
Single machine group
Multiple machine groups
Set a machine group number of each spindle
in "Spindle's machine group No. 1(#3196
mgrspnum1)"
Set a machine group number of each spindle
in "Spindle's machine group No. 2(#3197
mgrspnum2)"
Set "0"
Set "1"
IB-1501668-B