14.41 EcoMonitorLight Connection
EcoMonitorLight connection is a function to enable NC system to collect and manage the electric power of the machine tool
which is measured by the Mitsubishi Electric energy measuring unit "EcoMonitorLight".
The electric power (mainly consumed and regenerated power) of entire machine tool and peripheral devices can be
measured by connecting EcoMonitorLight to the main breaker of the machine tool or the breaker of the peripheral devices
(motor, coolant, etc.) which configure the machine tool. EcoMonitorLight can transmit each measured power value to external
devices with serial communication. By establishing serial communication (Modbus) between the NC unit and EcoMonitorLight
using a serial cable, the NC system can collect the power values of the entire machine tool and peripheral devices measured
by EcoMonitorLight.
Consequently, the electric power in the machine tool can be finely managed, which enables energy-saving operation.
[Power measurement by EcoMonitorLight and power collection by NC system]
Collects the
power values
Power
Supply
Modbus
RS-485
Up to 16 EcoMonitorLights are connectable in M8V Series.
The following two things are available with this function.
 Power values measured with EcoMonitorLight at a constant frequency (consumed and regenerated power values) are col-
lected.
Machine tool of consumed and regenerated power values can be collected from predetermined R register.
 Power values, which are measured with EcoMonitorLight by user operation other than the power values mentioned above,
are collected.
When inputting the information about the collection destination of EcoMonitorLight to R register, power values can be col-
lected from the predetermined R register.
IB-1501668-B
CNC display unit
CNC control unit
Main
breaker
Measures
the power
EcoMonitor
Light#1
Peripheral devices
Peripheral
devices' breaker
Modbus
RS-485
892
Measures
the power
EcoMonitor
Light#2