Operation When A Tool Has Reached The End Of Its Tool Life - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.15 Tool Life Management (Machining Center System)

14.15.5 Operation When a Tool Has Reached the End of Its Tool Life

When the tool exceeds the estimated tool life (hours) or the estimated number of cuttings, the "Tool life over" signal (XC2E) is
output.
For the tool life management II, when all the tools in the group have reached the end of their tool lives, the "Tool group life
over" signal (XC2F) is output.
When the "Tool life over" signal or the "Tool group life over" signal is output, operations (e.g. automatic operation) do not stop.
These signals can be temporarily canceled by the "Temporary cancel of tool life expiration ON" signal (XC2C) or the
"Temporary cancel of tool group life expiration ON" signal (XC2D).
For details, refer to "PLC Interface Manual".