M800V/M80V Series PLC Programming Manual (1/2)
8 Function Instructions
8.4 Data Transfer Instructions
EDMOV, EDMOVP: Floating-point data transfer (double precision)
Setting
Bit devices
data
X
Y
M
L
F
S
D
[Instruction symbol] [Execution condition]
EDMOV
EDMOVP
 Setting data
Setting data
S
Data to be transferred, or the number of the device storing data to be transferred. Real number
D
The number of the device that will store transferred data.
 Functions
 Transfers the 64-bit data from the device designated by (S) to the device designated by (D).
S+3
S+2
S+1
S
4.23542
64-bit floating-point real number
 When setting input values from programming tools, rounding errors may occur.
For precautions when setting input values from programming tools, refer to "6.3.4 Single/Double-Precision Real Number
Data".
 Operation errors
 There are no arithmetic errors associated with the EDMOV(P) instruction.
IB-1501667-B
Usable devices
B SB
T SM V
T
C
Command
Command
Meaning
D+3
D+2
D+1
Transfer
4.23542
64-bit floating-point real number
Con-
Word devices
stant
D
R/ZR W SW SD
Z
D
246
Digit
Pointer
designa-
Index
tion
E
P
indicates the sign "EDMOV".
S
D
P
S
D
Data type