M800V/M80V Series PLC Programming Manual (1/2)
3 Input/Output Signals
3.3 PLC Device Assignment of Digital Signal (DI/DO)
 Up to 24 stations can be specified for high-speed input/output specification each for input and output. If 25 or more stations
are specified, the alarm "Y05 Initial parameter error" will be issued.
 High-speed input/output specification can be set by R registers below as well as the RIO assignment parameters.
Channel No.
High-speed input
specification
RIO1
High-speed output
specification
High-speed input
specification
RIO2
High-speed output
specification
High-speed input
specification
RIO3
High-speed output
specification
Note
(1) Turn the power OFF and ON after the R register settings to enable the settings.
(2) One bit of each R register is equivalent to one station. The high-speed input/output specification can be performed by
turning ON the R register bits of the stations to be input or output with PC high speed. To output the 10th station of
RIO1 at high speed, for instance, turn bit9 of R30544 ON.
(3) High-speed input/output designation is disabled for the system-occupied stations of RIO3 and operation panel I/O
unit-connected channels.
Even when the bit6 to bitD of R30552 and R30568 are turned ON, they will be invalid.
(4) The above settings are invalid with fixed device assignment.
 In the following cases, the alarm "Y05 Initial parameter error" will be issued when the power is turned ON. The number of
the RIO assignment parameter with illegal setting state will be displayed.
- The value outside the range of setting has been set to the RIO assignment parameter (except "#53001 RIO dev
assign").
- Two or more stations of the target channel No. and the target station No. are set redundantly to the RIO assignment
parameters.
(Example) The power is turned ON in a state where the 1st and 2nd station of RIO1 are set redundantly to the RIO
assignment parameter #1 to #5 as shown in the table below. (Both the 1st and 2nd stations are connected to NC
control unit.)
Target channel No.
Parameter set No.#n
#n (parameter No.)
1
1 (#53011)
2
1 (#53021)
3
1 (#53031)
4
1 (#53041)
5
1 (#53051)
Result:
The parameter number (53031) of "Target channel #3" will be displayed on the alarm "Y05 Initial parameter error".
Duplication error of RIO1 second station will be detected first because the RIO assignment parameter is checked from the
top. Between the parameter set #2 and #3 to which second station of RIO1 are set, parameter set #3 which is the latter will
be displayed as the alarm.
- A PLC device outside the assignable range has been set to the RIO assignment parameter.
- 25 or more stations have been specified with the high-speed input or output with the RIO assignment parameters.
- The RIO assignment parameters have not been specified to the remote I/O unit stations with DI/DO functions (except
safety DI/DO) that are connected to NC.
- Two or more stations of the PLC devices are set redundantly to the RIO assignment parameters.
IB-1501667-B
1 to 8
9 to 16
17 to 24
R30544
R30544
R30545
low-order
high-order
low-order
R30560
R30560
R30561
low-order
high-order
low-order
R30548
R30548
R30549
low-order
high-order
low-order
R30564
R30564
R30565
low-order
high-order
low-order
R30552
R30552
R30553
low-order
high-order
low-order
R30568
R30568
R30569
low-order
high-order
low-order
Target station No.
#n (parameter No.)
0 (#53012)
1 (#53022)
1 (#53032)
0 (#53042)
0 (#53052)
22
Station No.
25 to 32
33 to 40
41 to 48
R30545
R30546
R30546
high-order
low-order
high-order
R30561
R30562
R30562
high-order
low-order
high-order
R30549
R30550
R30550
high-order
low-order
high-order
R30565
R30566
R30566
high-order
low-order
high-order
R30553
R30554
R30554
high-order
low-order
high-order
R30569
R30570
R30570
high-order
low-order
high-order
Setting state
RIO1 1st station is set
RIO1 2nd station is set
RIO1 2nd station is set
RIO1 1st station is set
RIO1 1st station is set
49 to 56
57 to 64
R30547
R30547
low-order
high-order
R30563
R30563
low-order
high-order
R30551
R30551
low-order
high-order
R30567
R30567
low-order
high-order
R30555
R30555
low-order
high-order
R30571
R30571
low-order
high-order