M800V/M80V Series PLC Programming Manual (1/2)
8 Function Instructions
8.4 Data Transfer Instructions
 Program example
 The following program stores the 64-bit floating-point real number at D10 to D13 to D0 to D3.
[Ladder mode]
SM400
0
4
 The following program stores the real number -1.23 at D10 to D13 when X8 turns ON.
[Ladder mode]
X8
0
4
EDMOVP D10 D0
END
[Operation]
D13
D12
D11
D10
36.475
EDMOVP E-1.23 D10
END
[Operation]
-1.23
[List mode]
Steps
Inst.
Device
0
LD
SM400
1
EDMOVP D10
D0
4
END
D3
D2
D1
D0
36.475
[List mode]
Steps
Inst.
Device
0
LD
X8
1
EDMOVP E-1.23
D10
4
END
D13
D12
D10
D11
-1.23