M800V/M80V Series PLC Programming Manual (2/2)
16 External PLC link
16.1 CC-Link
Master station
Remote output RY
RY F to RY 0
For station
No. 1
RY 1F to RY 10
RY 2F to RY 20
For station
No. 2
RY 3F to RY 30
RY 4F to RY 40
For station
No. 3
RY 5F to RY 50
For station
RY 6F to RY 60
No. 4
RY 7F to RY 70
For station
No. 5
RY 8F to RY 80
[Ver.2 RX/RY]
Master station -> Local station/Remote device station/Remote I/O station
 Master station
- The output status to the local station (RY), remote device station and remote I/O station (RX) is stored.
- The number of used points per station changes depending on the number of occupied stations and the extended cyclic
setting. (Refer to "16.1.1 Performance Specifications".)
- For remote I/O station, the number of used points can be set to 8 points, 16 points, or 32 points with parameter.
 Local station
- The data received from the remote device station, remote I/O station, and master station (RY) is stored.
- The number of used points per station changes depending on the number of occupied stations and the extended cyclic
setting. (Refer to "16.1.1 Performance Specifications".)
- For remote I/O station, the number of used points can be set to 8 points, 16 points, or 32 points with parameter of the
master station.
Note
(1) Refer to "CC-Link Specification manual" (BNP-C3072-089) on parameter setting.
Local station
Remote device station
(Station No.1 : Occupied
(Station No.2 : Occupied
1 station, set to "Double")
2 stations, set to "Single")
Remote input RX
Remote output RY
RX F to RX 0
RX 1F to RX 10
RX 2F to RX 20
RY0F to RY00
RX 3F to RX 30
RY1F to RY10
RX 4F to RX 40
RY2F to RY20
RX 5F to RX 50
RY3F to RY30
RX 6F to RX 60
RX 7F to RX 70
RX 8F to RX 80
919
Remote I/O station (Station No.4 :
Local station
Occupied 1 station, set to "Single")
(Station No.5 : Occupied
(8 points + 8 points reserved)
1 station, set to "Single")
Remote input RX
RX F to RX 0
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX 5F to RX 50
RX 6F to RX 60
Y07 to Y00
RX 7F to RX 70
RX 8F to RX 80
The last two bits of the local station cannot be used.