Timing Chart - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.32 Circular Feed in Manual Mode

14.32.4 Timing chart

The timing chart for the circular feed in manual mode is shown below.
Circular feed in
manual mode valid
Coordinate settings
Circular feed in
manual mode
Current position
Feed axis select
Axis movement
A: Moves in the normal mode.
B: Stops for the coordinate change.
C: Moves on the hypothetical coordinate that has been set.
D: Stops for the coordinate change.
Note
(1) Not only H and V axes but also the other axes stop during the coordinate change.
IB-1501668-B
Any change of the data is not valid
Current position is updated
A
B
794
Data is not
ensured
C
D