2. System Configuration

2.2 General Connection Diagram

2.2.1 Display Unit: FCU7-DA201-11/FCU7-DA211-11

R S T
Circuit breaker
ON
OFF
MC
MC
MC
24Vdc
Power Supply
ACIN
Circuit
breaker
RS-232C Device
OT release SW
EMG
RA
FG
OT release SW
EMG
F120 Cable
RA
FG
24Vdc
RS-232C Device
SIO x 2
FCUA-R030 Cable
Sensor signals. 8 pints
Manual pulse generator
UFO-01-2Z9
(5V)
Sync. Encoder
Dotted lines indicate the sections
prepared by machine tool builder
F070 Cable
24Vdc
24Vdc
DCOUT
G031/G032 Cable
FG
FG
F070 Cable
24Vdc
F120 Cable
LAN(user)
G300 Cable
Machine operation panel
(Max: 64/64)
LAN1
OPI
EMG
terminator
G123
EMG
CNC Unit
F070 Cable
DCIN
FCU7-MU001/MU002/MU011
F034/F035 Cable
SIO
SKIP
SKIP
ENC
SV1
SV2
RIO1
RIO2
G023/G024 Cable
(Max:20m)
FCUA-R050,R054 Cable
SH21 Cable
SH21 Cable
FCUA-R211 Cable(SH41 Cable)
2.2 General Connection Diagram
The unit names, cable names and various specifications are subject
to change without notice. Always confirm these details before placing
an order.
Display Unit FCU7-DA201/DA211
IC memory card interface
INV
CF
PC Board
LCD
DCIN
SIO
MENUKEY
FRONT_OUT
LAN
USB2
USB1
FCU7-KB021/KB022/KB041
G290 Cable
G301
Can be added onto
Cable
back of keyboard
LAN
G310 Cable
NCRST
Operation Panel
F020/F021/F022(12V) Cable
DCIN
G020/G021/G022(5V) Cable
I/O Unit
MPG
FCU7-
EMG
DX670/DX671
DX770/DX771
FCUA-R211 Cable(SH41 Cable)
DI:CG31/CG33
RIO3
DO:CG32/CG34
OPI
R300/R301Cable
G013Cable(max:20m)
Expansion Unit FCU7-EX89*
CF
Slot1
OPT1
SDIO
EXT-CON
MDS-D/DH
G380/G395/G396
Spindle/Servo
Remote I/O unit
FCUA-R211 Cable(SH41 Cable)
RIO1
RIO2
DX101
DCIN
24Vdc
Machine I/O
Remote I/O unit
RIO1
RIO2
DX101
DCIN
24Vdc
Machine I/O
3
IC memory card interface
Backlight
inverter
8.4-type/10.4-type
F480 Cable
LCD
G093 Cable
Menu key
G291 Cable
Keyboard Unit
Mouse
Manual Pulse generator HD60 (12V)
UFO-01-2Z9(5V)
Remote I/O unit
RIO1
RIO2
DX101
F070 Cable
DCIN
24Vdc
Machine I/O
Slot2
Slot3
FieldBus OPT2 etc
Drive Units
FCUA-R211
Remote I/O unit
(SH41)
To next unit or
RIO1
RIO2
terminator
DX101
DCIN
Max: 256/256
24Vdc
Machine I/O
FCUA-R211
Remote I/O unit
(SH41)
To next unit or
RIO1
RIO2
terminator
DX101
DCIN
Max: 256/256
24Vdc
Machine I/O
USB3
interface
USB
PC Keyboard
To next unit or
terminator
Max: 128/128