3. Data Formats

3.3 Program address check function

Function and purpose
The program can be checked in word units when operating machining programs.
Detailed description
(1) Address check
This function enables simple checking of program addresses in word units. If the alphabetic
characters are continuous, the program error (P32) will occur. Availability of this function is
selected by the parameter "#1227 aux11/bit4".
Note that an error will not occur for the following:
• Reserved words
• Comment statements
Example of program
(1) Example of program for address check
(Example 1) When there are no numbers following an alphabetic character.
(Example 2) When a character string is illegal.

3.4 Tape memory format

Function and purpose
(1) Storage tape and significant sections
The others are about from the current tape position to the EOB. Accordingly, under normal
conditions, operate the tape memory after resetting.
The significant codes listed in "Table of tape codes" in "3.1 Tape Codes" in the above
significant section are actually stored into the memory. All other codes are ignored and are not
stored.
The data between control out "(" and control in ")" are stored into the memory.
G28 X ; → An error will occur. Change to "G28 X0;", etc.
TEST ; → An error will occur. Change to "(TEST);", etc.