JUNOSe 11.1.x Command Reference Guide N to Z
Global Configuration
Mode
312
radius calling-station-format
VLAN (8 bytes)
Format for serial interfaces:
systemName (up to 4 bytes) slot (1 byte) adapter (1 byte) port (1 byte)
0 (8 bytes)
For E120 routers and E320 routers, adapter is the number of the bay in
which the I/O adapter (IOA) resides, either 0 (representing the right IOA bay
on the E120 router and the upper IOA bay on the E320 router) or 1
(representing the left IOA bay on the E120 router or the lower IOA bay on
the E320 router). For ERX7xx models, ERX14xx models, and ERX310 routers,
adapter is always shown as 0.
Slot numbers 0 through 16 are shown as ASCII characters in the 1-byte slot
field.
fixed-format-adapter-new-field Specifies that the RADIUS client uses a fixed
format of up to 17 characters consisting of all ASCII fields with a 2-byte slot field,
1-byte adapter field, and 2-byte port field:
Format for ATM interfaces:
systemName (up to 4 bytes) slot (2 bytes) adapter (1 byte) port (2 bytes)
VPI (3 bytes) VCI (5 bytes)
Format for Ethernet interfaces:
systemName (up to 4 bytes) slot (2 bytes) adapter (1 byte) port (2 bytes) VLAN
(8 bytes)
Format for serial interfaces:
systemName (up to 4 bytes) slot (2 bytes) adapter (1 byte) port (2 bytes)
0 (8 bytes)
For E120 routers and E320 routers, adapter is the number of the bay in
which the IOA resides, either 0 or 1. For ERX7xx models, ERX14xx models,
and ERX310 routers, adapter is always shown as 0.
Slot numbers 0 through 16 are shown as integers in the 2-byte slot field.
stacked Includes a 4-byte stacked VLAN (S-VLAN ID) for Ethernet interfaces
when the RADIUS client uses the fixed-format, fixed-format-adapter-embedded,
or fixed-format-adapter-new-field format; by default, these formats do not include
the S-VLAN ID unless you specify the optional stacked keyword:
Format for Ethernet interfaces that use fixed-format:
systemName (up to 4 bytes) slot (2 bytes) port (1 byte) S-VLAN (4 bytes) VLAN
(4 bytes)
Format for Ethernet interfaces that use fixed-format-adapter-embedded:
systemName (up to 4 bytes) slot (1 byte) adapter (1 byte) port (1 byte) S-VLAN
(4 bytes) VLAN (4 bytes)
Format for Ethernet interfaces that use fixed-format-adapter-new-field:
systemName (up to 4 bytes) slot (2 bytes) adapter (1 byte) port (2 bytes)
S-VLAN (4 bytes) VLAN (4 bytes)