Programming Guide | VLT® AutomationDrive FC 360
1-15 Low Speed Filter Time Const.
Default value:
Size related
Setup:
All setups
Data type:
Uint16
This time constant is used below 10% rated speed. Obtain quick control through a short damping time constant. However, if this value is
too short, the control becomes unstable.
1-16 High Speed Filter Time Const.
Default value:
Size related
Setup:
All setups
Data type:
Uint16
This time constant is used above 10% rated speed. Obtain quick control through a short damping time constant. However, if this value is
too short, the control becomes unstable.
1-17 Voltage Filter Time Const.
Default value:
Size related
Setup:
All setups
Data type:
Uint16
Reduces the influence of high frequency ripple and system resonance in the calculation of supply voltage. Without this filter, the ripples
in the currents can distort the calculated voltage and affect the stability of the system.
1-18 Min. Current at No Load
Default value:
0%
Setup:
All setups
Data type:
Uint16
Adjust the "Isd" current in no load situations to achieve a smoother motor operation.
1-2* Motor Data
4.2.3
This parameter group comprises input data from the nameplate on the connected motor.
Changing the value of these parameters affects the setting of other parameters.
1-20 Motor Power
Default value:
Size related
Setup:
All setups
Data type:
Uint8
Danfoss A/S © 2024.01
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
NOTICE
Parameter type:
Conversion index:
Change during operation:
Range (0.01–20.00 s)
-2
True
Range (0.01–20.00 s)
-2
True
Range (0.001–1.000 s)
-3
True
Range (0–50%)
0
True
Option
–
False
AU275649936274en-001401 / 130R0507 |
57
Need help?
Do you have a question about the VLT AutomationDrive FC 360 and is the answer not in the manual?
Questions and answers