Programming Guide | VLT® AutomationDrive FC 360
This parameter is active only during positioning if parameter 33-44 Positive Software Limit Active is set to [1] Active. When parameter
34-50 Actual Position reaches above the positive software limit set in this parameter, a position control fault alarm is reported.
33-43 Negative Software Limit Active
Default value:
[0] Inactive
Setup:
1 setup
Data type:
Uint8
When this parameter is set to active, the drive continuously checks whether the target position is below the negative software limit. If it
occurs, an error is issued and the drive control is switched off.
Option
[0]
[1]
33-44 Positive Software Limit Active
Default value:
[0] Inactive
Setup:
1 setup
Data type:
Uint8
When this parameter is set to active, the drive continuously checks whether the target position is above the positive software limit. If it
occurs, an error is issued and the drive control is switched off.
Option
[0]
[1]
33-45 Time in Target Window
Default value:
32 ms
Setup:
1 setup
Data type:
Uint8
Set the time in target window to determine whether the target position has been reached. This parameter works with parameter 33-47
Size of Target Window. A position is only viewed as reached when the actual position is within the target window.
33-46 Limit Value Of Delta Position In Target Window
Default value:
4
Setup:
All setups
Data type:
Uint16
288
| Danfoss A/S © 2024.01
Parameter type:
Conversion index:
Change during operation:
Name
Inactive
Active
Parameter type:
Conversion index:
Change during operation:
Name
Inactive
Active
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Option
True
Option
True
Range (1 ms–255 ms)
0
True
Range (1–10000)
0
True
AU275649936274en-001401 / 130R0507