17-21 Resolution (Positions/Rev)
Default value:
Size related
Setup:
All setups
Data type:
Uint32
Select the resolution of the absolute encoder, that is, the number of counts per revolution.
17-22 Multiturn Revolutions
Default value:
1
Setup:
All setups
Data type:
Uint32
Set the number of multi-turn revolutions. Selecting '1' means that the encoder is a single-turn type.
17-24 SSI Data Length
Default value:
13
Setup:
All setups
Data type:
Uint8
Set number of bits for the SSI telegram.
17-25 Clock Rate
Default value:
260 kHz
Setup:
All setups
Data type:
Uint16
Set the clock rate for the SSI clock. When having long cables the clock rate must be reduced.
17-26 SSI Data Format
Default value:
[0] Gray code
Setup:
All setups
Data type:
Uint8
Set the data format of the SSI data.
Option
[0]
[1]
Danfoss A/S © 2024.01
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Name
Gray code
Binary code
AU275649936274en-001401 / 130R0507 |
Range (4–1073741824)
0
False
Range (1–16777216)
0
False
Range (1–32)
0
False
Range (100–260 kHz)
0
False
Option
False
267