Programming Guide | VLT® AutomationDrive FC 360
Setup:
All setups
Data type:
Uint16
The reference signal bypasses the torque controller by an amount as specified.
7-19 Current Controller Rise Time
Default value:
Size related
Setup:
All setups
Data type:
Uint16
Adjust the response time of the current controller relative to the control period.
7-2* Process and Speed Ctrl.
4.8.3
Select the feedback sources for the process PID control, and how this feedback should be handled.
7-20 Process CL Feedback 1 Resource
Default value:
[0] No function
Setup:
All setups
Data type:
Uint8
The effective feedback signal is made up of the sum of up to 2 different input signals. Select which input is treated as the source of the
1st of these signals. The 2nd input signal is defined in parameter 7-22 Process CL Feedback 2 Resource.
Option
[0]
[1]
[2]
[3]
[4]
7-22 Process CL Feedback 2 Resource
Default value:
[0] No function
Setup:
All setups
Data type:
Uint8
The effective feedback signal is made up of the sum of up to 2 different input signals. Select which input is treated as the source of the
2nd of these signals. The 1st input signal is defined in parameter 7-22 Process CL Feedback 2 Resource.
Option
[0]
[1]
Danfoss A/S © 2024.01
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Name
No function
Analog Input 53
Analog Input 54
Frequency input 29
Frequency input 33
Parameter type:
Conversion index:
Change during operation:
Name
No function
Analog Input 53
AU275649936274en-001401 / 130R0507 |
0
True
Range (15–100%)
0
True
Option
–
True
Option
–
True