Programming Guide | VLT® AutomationDrive FC 360
Option
[0]
[1]
37-04 Pos. Velocity
Default value:
300 RPM
Setup:
1 setup
Data type:
Uint16
Define the velocity during positioning. The maximum value must not exceed the value specified in parameter 32-80 Maximum Allowed
Velocity.
37-05 Pos. Ramp Up Time
Default value:
5.00 s
Setup:
1 setup
Data type:
Uint16
It is defined as the time in milliseconds that it takes to ramp from standstill to parameter 32-80 Maximum Allowed Velocity.
37-06 Pos. Ramp Down Time
Default value:
5.00 s
Setup:
1 setup
Data type:
Uint16
It is defined as the time in milliseconds that it takes to ramp from parameter 32-80 Maximum Allowed Velocity to standstill.
37-07 Pos. Behavior After Reached
Default value:
[0] Coast&Brake
Setup:
1 setup
Data type:
Uint8
When the automatic brake control function is disabled, the drive controls the application also at standstill. When the automatic brake
control function is enabled, the mechanical brake is automatically activated every time the application is at standstill for a time period
specified in parameter 37-08 Pos. Hold Delay.
Option
[0]
[1]
Danfoss A/S © 2024.01
Name
Absolute
Relative
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Name
Coast & Brake
Zero Speed Hold
AU275649936274en-001401 / 130R0507 |
Range (1–30000 RPM), Array
[8]
0
True
Range (0.01–600.00 s), Array
[8]
-2
False
Range (0.01–600.00 s), Array
[8]
-2
False
Option
True
299