Programming Guide | VLT® AutomationDrive FC 360
Option
[14]
[15]
[16]
[17]
[18]
[19]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[32]
[33]
[34]
Danfoss A/S © 2024.01
Name
Select preset ref 4
Select preset ref 5
Select preset ref 6
Select preset ref 7
Select ramp 1
Select ramp 2
Run
Run reverse
Stop
Qstop
DC Brake
Coast
Freeze output
Start timer 0
Start timer 1
Start timer 2
Set digital out A low
Set digital out B low
Set digital out C low
Description
Select preset reference 4. If the active
preset reference is changed, it merges
with other preset reference commands
coming from either the digital inputs or
via a fieldbus.
Select preset reference 5. If the active
preset reference is changed, it merges
with other preset reference commands
coming from either the digital inputs or
via a fieldbus.
Select preset reference 6. If the active
preset reference is changed, it merges
with other preset reference commands
coming from either the digital inputs or
via a fieldbus.
Select preset reference 7. If the active
preset reference is changed, it merges
with other preset reference commands
coming from either the digital inputs or
via a fieldbus.
Select ramp 1.
Select ramp 2.
Issue a start command to the drive.
Issue a start reverse command to the
drive.
Issue a stop command to the drive.
Issue a quick stop command to the drive.
Issue a DC brake command to the drive.
The drive coasts immediately. All stop
commands including the coast command
stop the SLC.
Freeze the output of the drive.
See parameter 13-20 SL Controller Timer
for further description.
See parameter 13-20 SL Controller Timer
for further description.
See parameter 13-20 SL Controller Timer
for further description.
Any output with SL output A is low.
Any output with SL output B is low.
Any output with SL output C is low.
AU275649936274en-001401 / 130R0507 |
227