Programming Guide | VLT® AutomationDrive FC 360
Option
[0]
[2]
[4]
37-1* Position Control
4.25.2
37-01 Pos. Feedback Source
Default value:
[0] 24 V Encoder
Setup:
1 setup
Data type:
Uint8
Select position feedback source.
Option
[0]
[1]
[2]
[3]
37-02 Pos. Target
Default value:
0
Setup:
1 setup
Data type:
Int32
If parameter 37-03 Pos. Type is set to [0] Absolute, the target position is an absolute position (relative to home position). If the parameter
37-03 Pos. Type is set to [1] Relative and the last position was obtained through jogging, the target position is relative to that position.
If the last position was reached as a result of a positioning command, then the target position is relative to the last target position
regardless of being reached or not.
37-03 Pos. Type
Default value:
[0] Absolute
Setup:
1 setup
Data type:
Uint8
Define the target position type.
298
| Danfoss A/S © 2024.01
Name
Drive mode
Position Control
Position Control with Laser Encoder
Parameter type:
Conversion index:
Change during operation:
Name
24 V Encoder
MCB102
MCB103
MCB102_ABS
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Option
False
Range (-1073741824–
1073741824), Array [8]
0
True
Option, Array [8]
False
AU275649936274en-001401 / 130R0507