Illustration 3.3 Path in the Hardware Catalog Open a project, set up the hardware, and add a PROFINET master system. Select Danfoss FC PN, then drag and drop it onto the PROFINET IO system. Illustration 3.1 Import the GSDML File in the Configuration...
The PROFIdrive profile, see chapter 4.4 PROFIdrive 1000 hex 12.5 Control Profile, or 2000 hex • The Danfoss FC control, see chapter 4.5 FC Drive 3000 hex 37.5 Control Profile. 100% 4000 hex Select the control profile in parameter 8-10 Control Word Table 4.7 Actual Speed for MRV/MAV...
Bit 03 = 1 enables the frequency converter to start the motor if the other starting conditions have been fulfilled. To select Danfoss FC protocol in the control word, set NOTICE parameter 8-10 Control Word Profile to [0] FC profile. Use the...
I/O controller program stopped execution. control word is received within this time, the frequency converter issues alarm 17, and execute one or more The Danfoss FC series frequency converters have two commands: separate functions to monitor and indicate communi- •...
Page 56
Table 8.17 Warnings and Alarms Code List 1) These faults may be caused by mains distortions. Installing a Danfoss line filter may rectify this problem. 2) For enclosure size J7, the warning can also be caused by high UDC voltage.
Page 60
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.