Programming Guide | VLT® AutomationDrive FC 360
12-93 Cable Error Length
Default value:
0
Setup:
1 setup
Data type:
Uint16
If cable diagnostics is enabled in parameter 12-90 Cable Diagnostic, the built-in switch is possible via time domain reflectometry
(TDR). This is a measurement technique which detects common cabling problems such as open circuits, short circuits, and impedance
mismatches or breaks in transmission cables. The distance from the option to the error is shown in meters with an accuracy of ±2 m (6.6
ft). The value 0 means no errors detected.
12-94 Broadcast Storm Protection
Default value:
-1%
Setup:
1 setup
Data type:
Int8
The built-in switch is capable of protecting the switch system from receiving too many broadcast packages, which can use up network
resources. The value indicates a percentage of the total bandwidth that is allowed for broadcast messages.
Example:
OFF means that the filter is disabled - all broadcast messages are passed through. The value 0% means that no broadcast messages are
passed through. A value of 10% means that 10% of the total bandwidth is allowed for broadcast messages. If the number of broadcast
messages exceeds the 10% threshold, they are blocked.
12-95 Broadcast Storm Filter
Default value:
[0] Broadcast only
Setup:
1 setup
Data type:
Uint8
Apply to parameter 12-94 Broadcast Storm Protection, if the broadcast storm protection also includes multicast telegrams.
Option
[0]
[1]
12-96 Port Config
Default value:
Size related
Setup:
1 setup
Data type:
Uint8
Enable or disable the port mirroring function.
Danfoss A/S © 2024.01
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Name
Broadcast only
Broadcast & Multicast
Parameter type:
Conversion index:
Change during operation:
AU275649936274en-001401 / 130R0507 |
Range (0–65535), Array [2]
0
True
Range (-1%–20%)
0
True
Option
True
Option
True
209

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 360 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents