Danfoss VLT AutomationDrive FC 360 Programming Manual page 232

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Programming Guide | VLT® AutomationDrive FC 360
Option
[0]
[1]
14-05 PWM Generation
Default value:
[0] Standard
Setup:
All setups
Data type:
Uint8
Select for PWM generation.
Option
[0]
[1]
14-07 Dead Time Compensation Level
Default value:
Size related
Setup:
All setups
Data type:
Uint8
Level of applied dead time compensation in percentage.
A high level (>90%) optimizes the dynamic motor response.
l
A level 50–90% is good for both motor-torque-ripple minimization and the motor dynamics.
l
A 0-level turns off the dead time compensation.
l
14-08 Damping Gain Factor
Default value:
Size related
Setup:
All setups
Data type:
Uint8
Damping factor for DC-link voltage compensation.
14-09 Dead Time Bias Current Level
Default value:
Size related
Setup:
All setups
Data type:
Uint8
Set a bias signal (in [%]) to add to the current-sense signal for dead time compensation.
230
| Danfoss A/S © 2024.01
Name
Off
On
Parameter type:
Conversion index:
Change during operation:
Name
Standard
Double Update
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
Disable the function.
Select [1] On to transform the acoustic
motor switching noise from a clear ring
tone into a less audible white noise.
Option
False
Description
Standard setting.
Mainly for high speed applications.
Range (0–100)
0
False
Range (0–100%)
0
True
Range (0–100%)
0
False
AU275649936274en-001401 / 130R0507

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 360 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents