Programming Guide | VLT® AutomationDrive FC 360
Setup:
All setups
Data type:
Uint8
The drive provides higher current than normal current levels to enhance breakaway-torque capacity.
Option
[0]
[1]
4-25 Power Limit Motor Factor Source
Default value:
[0] No function
Setup:
All setups
Data type:
Uint8
Set an analog input to scale the motoric power limit set in parameter 4-82 Power Limit Motor Mode from 0% to 100%.
Option
[0]
[2]
[4]
[6]
[8]
4-26 Power Limit Gener. Factor Source
Default value:
[0] No function
Setup:
All setups
Data type:
Uint8
Set an analog input to scale the generatoric power limit set in parameter 4-83 Power Limit Generator Mode from 0% to 100%.
Option
[0]
[2]
[4]
[6]
[8]
102
| Danfoss A/S © 2024.01
Conversion index:
Change during operation:
Name
Off
On
Parameter type:
Conversion index:
Change during operation:
Name
No function
Analog in 53
Analog in 53 inv
Analog in 54
Analog in 54 inv
Parameter type:
Conversion index:
Change during operation:
Name
No function
Analog in 53
Analog in 53 inv
Analog in 54
Analog in 54 inv
False
Option
True
Option
True
AU275649936274en-001401 / 130R0507