Programming Guide | VLT® AutomationDrive FC 360
Option
[0]
[1]
[2]
[3]
[4]
[5]
[6]
17-7* Position Scaling
4.16.6
17-72 Position Unit Numerator
Default value:
1
Setup:
All setups
Data type:
Int32
Set the position unit numerator.
17-73 Position Unit Denominator
Default value:
1
Setup:
All setups
Data type:
Int32
Set the position unit denominator.
17-74 Position Offset
Default value:
0
Setup:
All setups
Data type:
Int32
Set the position offset.
Parameter Group 18-** Data Readouts 2
4.17
18-3* Analog ReadOuts
4.17.1
18-37 Temp. Input X48/4
Default value:
0
Setup:
All setups
Data type:
Int16
270
| Danfoss A/S © 2024.01
Name
Disabled
Warning
Trip
Jog
Freeze Output
Max Speed
Switch to Open Loop
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Range (-16777215–16777215)
0
False
Range (-16777215–16777215)
0
False
Range (-2147483647–
2147483647)
0
False
Range (-500–500)
0
True
AU275649936274en-001401 / 130R0507