Programming Guide | VLT® AutomationDrive FC 360
Enter the limit for the motor speed when the rotation direction is clockwise.
4-94 Negative Speed Limit [Hz]
Default value:
Size related
Setup:
All setups
Data type:
Uint16
Enter the limit for the motor speed when the rotation direction is counterclockwise.
4-95 Positive Torque limit
Default value:
Size related
Setup:
All setups
Data type:
Uint16
Enter the limit for the motor torque when the torque direction is clockwise.
4-96 Negative Torque limit
Default value:
Size related
Setup:
All setups
Data type:
Uint16
Enter the limit for the motor torque when the torque direction is counterclockwise.
Parameter Group 5-** Digital In/Out
4.6
5-0* Digital I/O mode
4.6.1
Parameters for configuring the input and output using NPN and PNP.
5-00 Digital Input Mode
Default value:
[0] PNP
Setup:
1 setup
Data type:
Uint8
Set NPN or PNP mode for digital inputs.
Option
[0]
[1]
110
| Danfoss A/S © 2024.01
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Name
PNP
NPN
Range (0.0–500.0 Hz)
-1
True
Range (0.0–160.0%)
-1
True
Range (0.0–160.0%)
-1
True
Option
–
False
Description
Action on positive directional pulses (0).
PNP systems are pulled down to ground
(GND).
Action on negative directional pulses
(1). NPN systems are pulled up to +24 V,
internally in the drive.
AU275649936274en-001401 / 130R0507