Programming Guide | VLT® AutomationDrive FC 360
34-5* Process Data
4.23.3
Readout of process data for motion control.
34-50 Actual Position
Default value:
0
Setup:
All setups
Data type:
Int32
The actual position in user unit.
34-56 Track Error
Default value:
0
Setup:
All setups
Data type:
Int32
Readout of the error between calculated command position and actual position in user unit.
Parameter Group 35-** Sensor Input Option
4.24
More Information
4.24.1
Parameter Group 35-** Sensor Input Option is only valid when VLT® Sensor Input MCB 114 is installed.
35-0* Temp. Input Mode
4.24.2
35-01 Term. X48/4 Input Type
Default value:
[0] Not Connected
Setup:
All setups
Data type:
Uint8
View the temperature sensor type detected at input X48/4.
Option
[0]
[1]
[3]
[5]
[7]
Danfoss A/S © 2024.01
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
  NOTICE
Parameter type:
Conversion index:
Change during operation:
Name
Not Connected
PT100 2-wire
PT1000 2-wire
PT100 3-wire
PT1000 3-wire
Range (-1073741824–
1073741824)
0
True
Range (-2147483647–
2147483647)
0
True
Option
True